Hp microserver software raid 5

A while ago i got a hp microserver gen8 with all four drive bays filled as a place to store and encode my media. I have set up the raid array using hps configuration tool, and it seems to be recognised during the boot process. Software raid, ubuntu, hp microserver linuxunix neowin. If there is a detailed tutorial anywhere that would be great, otherwise. Embedded raid setup instructions are located in the microserver user guide. Installing a hdd in the optical drive bay on an hp. The hp n40l has 2 cpu cores and supports up to 8gb of ram. Hp proliant microserver 7 g and for few months was working without problem, but today morning the storage was inaccesible. Hp smart array p212 zm is known to work flawlessly in the microserver and it connects directly to the standard sff8087 cable coming from the hdd backplane rerouting of the hdd sas cable is required to reach the connector on the controller 1. Some products seem almost too good to be true and i think the hp proliant microserver n40l is one of them. Microserver gen8 and raid 5 hewlett packard enterprise.

This mode is probably the best mode for zfs as there seems to be no raid controller firmware active between the disks and zfs. There is no connector for a battery in the microserver gen8. Jul 29, 2012 if you want to make a nas out of this device you want to go for raid 5. Its software raid on the microserver ps the web interface for the raid will allow the creation of raid 10 arrays but they wont survive a reboot. According to hp it is a integrated 4 port sata raid. How to configure raid 5 on hp proliant dl380 g7 youtube. Calling experts with hp gen8 microserver i would like to create a raid 5 with my server as it currently has 4 hds and am running out of space and would rather make most of the hds. Esxi v6 on hp proliant with raid vmware communities. Flexible data protection recovery flexible data protection recovery is a feature of intel rapid storage technology software. Need advice hp microserver gen8, raid 1, and expanding reddit. Server entrylevel hpe proliant microserver gen10 x3216 1p 8 gbu 4 sata nhp lff 200 w ps. At one point i remember being able to access the onboard raid functionality by activating raid in the bios, and then with ctrlf when the raid message comes on the screen during boot, accessing the raid configuration menu. It is a great box, but is missing one big thing which is raid 5 capability.

Am aware of the limited supported the b120i raid controller has and i. These drivers cause problems with the data stores and thus the b120i raid controller of the hp microserver gen8. I want to setup a new raid 5 with the 3 drives in my n54l microserver running windows server 2012. Hp proliant dl360 g6 1u 64bit server with 2xquadcore x5550 xeon 2. For now, i only have a virtual machine running on it, but im just starting. Dec 27, 2012 hi, so i have currently got the system running whs on the internal drive with no issues. I have an old microserver n40l with equal drives a a lab machine. The only way you are going to get raid 5 is by putting in another raid card, which is what i did p212. Press f11 on bootup to boot server from cd\dvd drive.

Hello communitynow that i achieved booting my microserver gen8 from ssd i want to know wheter i should use the omv internal raid for mirroring two drives or go for with the builtin raid controller of the microserver. The hp array configuration utility is a webbased application that helps you configure hp proliant smart2 array controllers, hp proliant smart array controllers, hp proliant integrated smart array controllers, and hp proliant storageworks raid array controllers. Need advice hp microserver gen8, raid 1, and expanding. But most importantly, like its brother the b140i trouble installing esxi 5.

The top of the unit has a slim optical drive bay, however we suspect most people will use it for a ssd. If one hard drive fails, raid 5 allows data to be recovered from the other two hard drives. It seems that a new and faster version is on the horizon. Also looking to test to see how much faster a hp p410 dedicated raid card is going to be in this machine raid 5 versus trying to set up a slower raid off this system. Id like to add some disks, can you confirm this is the steps i.

Google authenticator update adds dark mode, tool to transfer accounts between devices. It contains the amd equivalent of intels atom processor, the turion ii neo n40l dualcore, which runs at 1. Aug 12, 2017 0 raid 0 splits data evenly across two or more disks, without parity information, redundancy, or fault tolerance. Microserver n40l raid configuration not coming up hp. Quickspecs hp proliant microserver standard features da 716worldwide quickspecs version 14 992011 page3.

The main reason raid 5 is not supported with the b120i is the controller as configured in the microserver gen8 doesnt have a cache module. Hate to burst your bubble, but the b120i only supports raid 5 with a battery for the cache. Hp proliant ssd raid configuration hpe hardware spiceworks. Enable sata raid functionality in rbsu enabling the sata raid feature in rbsu on page 33. Hp proliant ml30 gen10 tower server, intel xeon e2124 quadcore 3. Nov 09, 2012 now youve got only 3 x 2tb drives to use as a data pool 6tb in raid 0, 4tb in raid 5, and youve split your data storage into two areas, one of just under 2tb and another of, say, 6tb. Overview of the raid 5 rebuild process in a redundant array of independent disks raid configuration, data are stored in arrays of drives to provide fault tolerance and improved data access performance. Select the array controller dynamic smart array b120i raid and then click configure button under actions section. Jul 25, 2011 hi kenneth, imho the hp microserver is a pretty good lab solution for either an esxi host or for a shared storage appliance assume youll have to use software based raid from the underlying os as the onboard raid controller isnt a 100% hardware based raid solution. By downloading, you agree to the terms and conditions of the hewlett packard enterprise software license agreement. Does the hp micro server have hardware or software raid. On the hp support site you can find a link to the amd download page where you can download the chipset driver which also includes the.

Although this is quite low for a hypervisor, it should be sufficient for a pure test environment. Now youve got only 3 x 2tb drives to use as a data pool 6tb in raid 0, 4tb in raid 5, and youve split your data storage into two areas, one of just under 2tb and another of, say, 6tb. Hp microserver use hp raid controller or omv software raid. Hpe proliant microserver gen10 is a compact and uniquely designed server that is ideal for small and home offices looking to build the first it server environment with a form factor that is easy to use. How i set up a raid 5 on my hp microserver gen8 patrick muff. This microserver has a built in raid controller that i have read is supported by esxi. In this video i show you how to configure raid 5 on hp proliant dl380 g7. Hp microserver n40l raid utility and driver thomas maurer. Configuring raid on hp proliant microserver focused it. Hi all, i just bought a hpe microserver gen10 x3421 and i wish to set it up with proxmox ve. Jul 24, 2019 hi all, i just bought a hpe microserver gen10 x3421 and i wish to set it up with proxmox ve. Hpe microserver gen10 x3421 8gb ram 2 x 2tb wd red hdd 1 x 240gb samsung 840 pro what would be the best.

I have set up the raid array using hp s configuration tool, and it seems to be recognised during the boot process. In order to get the desired raid 5 i had to resort to a softwarebased solution. If you are into the market for a very small, silent, efficient, yet capable home server, please take this device into consideration. It does have raid0 and raid1, but raid0 does not provide any protection and raid1 wastes too much space. Hp proliant microserver n40l is a great nas or router. I intend to run a linuxbased software raid5, because i do not want to rely on the controller hardware and raid5 isnt supported anyway. Quickspecs hp proliant microserver standard features da 716worldwide quickspecs.

You can use the array configuration utility for several tasks such as configuring. It is a great box, but is missing one big thing which is raid5 capability. How to configure raid 1 on a hp microserver youtube. Zfs performance on hp proliant microserver gen8 g1610t. If you want to use the local disks as an array, you have to buy an additional raid controller. I am specing out a raid upgrade on a hp proliant dl380 gen9 with the p440ar raid controller. In a raid 5 array configuration, the user data and parity data encoded redundant information are distributed across all the drives in the. Power outage is no concern to me as i am using an ups. What changes need to be made to the bios prior to setting up the raid 2. Hp microserver n36l added a lsi 92118i raid controller and now cant see embedded raid card.

As you can see, i have set up 2x 1tb drives with raid 1. Windows raid is totally software and will work on any pc. How to recover from a raid 1 disk failure on hp proliant. Hpe proliant microserver gen10 hpe store united kingdom. Hi, so i have currently got the system running whs on the internal drive with no issues. The supported optional controller has cache, smart array p222 controller part number 631667b21. Press c to configure the discs accordingly and save your settings.

Its software raid on the microserver ps the web interface for the raid will allow the creation of raid 10 arrays but they wont survive a. When setting up the raid with the b120i i ran into the first issue this hardware raid controller is only able to create raid 0, 1 or 10 logical volumes. Aug 14, 2015 the fifth sata port is not bootable if you disable the onboard raid controller and run in pure ahci mode. Now after setting up my hp microserver n40l as a windows homeserver i had to install the utilities to monitor the raid and other hardware.

The other option would be a raid 0 on the 4 drives with just backing up select data to the 2 tb to reduce the hard drive failure risk. Sep 26, 20 in this video i show you how to configure raid 5 on hp proliant dl380 g7. First, we are going to look at the general purpose server hardware. Upon unboxing the hpe proliant microserver gen10, one will immediately notice a diminutive stature. Watch out for the raid configuration menu and press f to configure. Esxi does not and has never supported software raid aka fakeraid controllers. In order to get the desired raid 5 i had to resort to a software based solution. It does have raid 0 and raid 1, but raid 0 does not provide any protection and raid 1 wastes too much space. We have the software raid option and used the pcie slot for a faster nic. By default, the hp thingy has created a raid 1 mirror with my two 1 tb drives. Select the drive you want to add to the array my case 2 wd red 3tb and then click create array. Some software requires a valid warranty, current hewlett packard enterprise support contract, or a license fee. Hi all, ive received my gen8 and managed to install esxi on it. We have the ilo 5 option with ilo essentials license.

Im sort of reluctant to try that in case i lose all of the data on the raid. The server does only have a software based raid controller which will not work with the esx. I have backups so i am going to unraid the hdds and bung on windows server 2012 r2 and make use of storage spaces as opposed to hps offering of raid, which really isnt a proper raid system to begin with. Now i am in a situation where i am running on a single physical disk and cant recover my raid 1 configuration. Hpe proliant microserver gen10 x3418 1p 8gbu 4lff nhp 200w ps perf server. I am looking at hp microserver for use in several places. Microserver raid5 hewlett packard enterprise community.

Buy an additional hardware raid controller that supports raid 5. For example one of my hp microserver gen8 servers has 2x8tb wd red disks in raid1, and gave me around 30mbs performance at best. The raid controller in this particular microserver is a fakeraid controller. Raid 5 raid 5 distributes data across three hard drives. The server does only have a softwarebased raid controller which will not work with the esx.

The main disadvantage is that the failure of one drive will cause the entire array to fail. Hpe proliant microserver gen10 plus specifications. I need to update a server in a single server school and might use a micro server as a holding area for files and server rolls while i update the old server but would prefer it has hardware raid. I know i can get a raid card for it, but that costs a lo. Hi kenneth, imho the hp microserver is a pretty good lab solution for either an esxi host or for a shared storage appliance assume youll have to use software based raid from the underlying os as the onboard raid controller isnt a 100% hardware based raid solution. Hi all, i have an old microserver n40l with equal drives a a lab machine. Youre better off using software raid or fitting an hp smart array p410 controller into the server for proper hardware raid. By using a small hd say 250gb in the top bay just for the whs 2011 installation you have 4 x 2tb to use as your data pool 6tb in raid 5, 8 tb in raid 0. To restore each lost stripe, the raid 5 rebuild process requires one read request from each of the operational drives n1 read requests, and one write request to the replacement drive.

We are then going to focus on the storagecentric aspects of the server. Hpe proliant microserver gen10 x3216 1p 8gbu 4lff nhp sata 200w ps entry server. Use linux or bsd software raid and dont spend a dime. I think the hp proliant microserver gen8 is a very interesting little box if you want to build your own zfsbased nas. Hp microserver n36l added a lsi 92118i raid controller. Amd opteron x3216 1,63,0 ghz, 2 core, 4 core di grafica, 1 mb, 1215w udimm da 8 gb 1x8 gb non incluse, 4 unita lff sata hpe non hotplug supportate. Currently the raid setup on the machine is using 8 300 gb 10k sas drive in raid 60, which is entirely incorrect.

460 119 57 413 332 1504 507 894 842 194 492 1164 1103 572 197 1117 341 687 1347 1242 862 1129 1473 1205 184 302 796 1434 712 930 185 884 163 1262 1271 196 607 651 500 1417 1390